Atmospheric Leaching of Copper in +0.5 mm Crushing Product from the Spent Lithium-Ion Batteries in Ammoniacal Solutions
Received:December 01, 2010            
View Full Text  View/Add Comment  Download reader
DOI:DOI:10.3969/j.issn.1007-7545.2011.03.001
KeyWord:Spent lithium-ion batteries; Copper; Ammonia leaching; Mechanical dismantling
                 
AuthorInstitution
WU Cai-bin 华东交通大学土木建筑学院
ZHANG Tao 华东交通大学土木建筑学院
WANG Cheng-yan 北京矿冶研究总院
LI Dun-fang 北京矿冶研究总院
MIN Lu-yan 华东交通大学土木建筑学院
LIU Jie 华东交通大学土木建筑学院
Hits: 3063
Download times: 26
Abstract:
      Ammoniacal solution system containing ammonia and ammonium carbonate was used as leaching media for the removal of copper in the +0.5 mm crushing product from the spent lithium-ion batteries (LIBs). Leaching test was carried out at room temperature and under normal atmospheric pressure conditions by introduction of air. The experimental results showed that when the aeration was 50 L/h, the reaction time was 7 h, and the solution was not stirred, all copper could be absolutely leached out in the 1∶9(v/v) solution systems, while in 1∶19 and 1∶4 solution systems, the copper leaching rate was 94.71% and 66.62% respectively. When the aeration was 25 L/h, leaching out all the copper in the 1∶9 solution needed 23 h, but stirring can quicken the reaction speed, in this case, the leaching time could be reduced to 3 h, while under the aeration was 50 L/h, the leaching time was reduced from 7 h to 2 h. Besides, the pH presents the regularity of gradually decreasing in the process.