      The casing tube heat exchanger in digestion process of alumina was studied, the heat transfer process was analyzed by means of engineering analysis and the heat transfer coefficients of three different casing tubes including single casing pipe, triple casing pipe and quadruple casing pipe were compared in digestion process of alumina. The results show that the triple-pipe gives the better heat transfer coefficient under the same slurry flow rate.