Study on Treatment of High Arsenic Copper Concentrate with Flash Smelting
           Published Online:January 22, 2018
View Full Text  View/Add Comment  Download reader
DOI:
KeyWord:flash smelting; flash converting; high arsenic copper concentrate; dust
  
AuthorInstitution
TANG Bin, WANG Wei, LIU Yang 中国瑞林工程技术有限公司冶金事业部
Hits: 1630
Download times: 2079
Abstract:
      Treatment of high arsenic copper concentrate with flash smelting was discussed. Metallurgical calculation was carried out according to arsenic distribution in one “double-flash” smelter in China. To address exceeding arsenic content in anode copper, dust recovery from electric dust collector was put forward. Feasibility of this process is demonstrated through production data and industrial test of one double-flash smelter. The results show that arsenic content can be reduced by 20% and arsenic in anode copper can meet requirement after electric dust collection. “Double-flash” process can effectively treat high arsenic copper concentrate.
Close