| Heat Balance Calculation of Slag Layer for ISA Furnace Spray Gun |
|
Received:March 30, 2012
Revised:March 31, 2012
Accepted:April 01, 2012
Published Online:September 19, 2012
|
| View Full Text View/Add Comment Download reader |
| DOI:10.3969/j.issn.1007-7545.2012.10.004 |
| KeyWord:ISA furnace; spray gun; slag layer; heat balance; calculation |
| Author | Institution |
| LI DONG |
昆明理工大学 冶金与能源工程学院 |
| ZHU Yun |
昆明理工大学 冶金与能源工程学院 |
|
| Hits: 2544 |
| Download times: 2583 |
| Abstract: |
| The spray gun for ISA furnace was tested in accordance with 1∶23 real size scale. The datas of vertical height and horizontal thickness of slag, as well as the water temperature in and out were obtained. Meanwhile, the heat balance for steady-state heat conduction process of the slag was calculated. The results show that the relationship between vertical height (h) of slag layer and the outer wall temperature (t) of the spray gun is 367.668t 1972828.44=exp(20.196918-45.798h). According to this formula, the temperature of spray gun outer wall at the top of the slag layer is 912 ℃, which is correspond with the actual measurement of 908 ℃. The heat balance calculation is proved to be correct and reasonable. |
| Close |