Study on Anolyte Purification Process of Anodic Electrolyte of High Copper-bearing Nickel Sulfide
Received:April 11, 2012   Revised:April 12, 2012   Accepted:April 13, 2012      Published Online:September 19, 2012
View Full Text  View/Add Comment  Download reader
DOI:10.3969/j.issn.1007-7545.2012.10.003
KeyWord:nickel sulfide; anodic electrolyte; anolyte; purification
     
AuthorInstitution
Zhao Lei 北京矿冶研究总院
Liu Daxing 北京矿冶研究总院
Hits: 2643
Download times: 2708
Abstract:
      The anolyte of anodic electrolyte of high copper-bearing nickel sulfide was treated by means of the purification process of copper extraction, removing iron and part of lead and arsenic with precipitation, cobalt extraction, lead deeply removing with ion exchange. The results show that this process has the advantages of short flowsheet, good flexibility of raw material, completely metal separation, and high metal recovery. Furthermore, the qualified nickel catholyte is prepared.