Study on Dilution of Copper Side Blowing Smelting Slag with Direct Current
Received:May 10, 2012   Revised:May 20, 2012   Accepted:May 21, 2012      Published Online:October 23, 2012
View Full Text  View/Add Comment  Download reader
DOI:10.3969/j.issn.1007-7545.2012.11.006
KeyWord:copper slag; dilution; direct current; ore-smelting electric furnace; recovery; oxygen enrichment side blowing smelting
     
AuthorInstitution
WEI Qi-jin 北京矿冶研究总院
YUAN Chao-xin 北京矿冶研究总院
Hits: 2016
Download times: 2691
Abstract:
      The water quenching copper slag from oxygen enrichment side blowing smelting process was diluted in laboratory through alternating current (AC) and direct current (DC) ore-smelting electric furnace. The results show that copper content in slag is reduced from 0.73% to 0.28% after 60 minutes dilution with bottom-cathode DC. The copper recovery is about 65%, increasing 10 percentage compared with that with AC. A variety of slag temperature between 1 160~1 350 ℃ has no obvious effect on copper recovery. With the dosage of pyrite concentrate of 10% of slag quantity, the copper content in slag will decrease to 0.24%, and the copper recovery is about 70%. The copper content in slag increases slowly with the increase of matte grade.