| Study on Occurrence of Hot Cells in Multipole Magnesium Electrolyzer |
|
Received:July 20, 2012
Revised:July 26, 2012
Accepted:July 27, 2012
Published Online:November 26, 2012
|
| View Full Text View/Add Comment Download reader |
| DOI:10.3969/j.issn.1007-7545.2012.12.008 |
| KeyWord:magnesium electrolysis; electrolytic cell; occurrence of hot cell; measurement |
| Author | Institution |
| zhouyunying |
攀枝花钢企欣宇化工钛业分公司 |
| shiyuying |
攀枝花钢企欣宇化工钛业分公司 |
|
| Hits: 3418 |
| Download times: 3055 |
| Abstract: |
| Hot cells frequently occurred in electrolytic process of magnesium. The second reaction between magnesium metal and chlorine abnormally led to rise of electrolyzer temperature, decrease of current efficiency and production reduction in single cell. This phenomenon in multipole magnesium electrolyzer is analyzed with in-depth discussion and the measures are put forward. |