| Study on Cobalt Leaching in Co (Ⅲ)-Na2SO3-H2SO4 System |
|
Received:September 24, 2012
Revised:September 26, 2012
Accepted:September 28, 2012
Published Online:April 23, 2013
|
| View Full Text View/Add Comment Download reader |
| DOI:10.3969/j.issn.1007-7545.2013.05.005 |
| KeyWord:cobalt; concentrated sulfuric acid; leaching rate; filtering performance; polyacrylamide |
| Author | Institution |
| LU Sujun |
金川镍钴研究设计院 |
| WANG Shuyou |
金川镍钴研究设计院 |
| ZHUGE Fuyu |
金川镍钴研究设计院 |
| ZHANG Han |
金川镍钴研究设计院 |
| ZHANG Peng |
金川镍钴研究设计院 |
|
| Hits: 2737 |
| Download times: 2848 |
| Abstract: |
| Cobalt-bearing raw materials were reduction leached in sulfuric acid system. The effects of dosage of sulfuric acid and sodium sulfite, leaching temperature, dosage of polyacrylamide on leaching rate of cobalt and the filtering performance were investigated. The results show that the leaching rate of cobalt is above 97% and the filtering performance is favorable under the optimum conditions including (for 1 kg raw materials) ratio of liquid to solid of 5∶1, leaching temperature of 60 ℃, dosage of concentrated sulfuric acid of 400 mL, dosage of sodium sulfite of 360 g, dosage of polyacrylamide of 20~40 mL, and pH value of terminal of 1.0~1.5. |
| Close |