| Optimization of Startup and Shutdown Mode of Molten Salt Heating System and Calculation of Salt Level in Bayer Process |
|
Received:February 26, 2014
Revised:March 03, 2014
Accepted:March 04, 2014
Published Online:July 21, 2014
|
| View Full Text View/Add Comment Download reader |
| DOI:doi:10.3969/j.issn.1007-7545.2014.08.007 |
| KeyWord:molten salt heating system; high temperature molten salt; improvement; startup and shutdown mode; prevention measures |
| Author | Institution |
| Li Fengjie |
河南中美铝业有限公司 |
| Zhao Haifeng |
河南中美铝业有限公司 |
|
| Hits: 2072 |
| Download times: 3248 |
| Abstract: |
| The calculation formula of volume of molten salt, calculation formula of molten salt density under different temperatures, and iterative calculation formula of liquid level of salt tank in piping dissolving molten salt heating system were derived. The quantitative effect of temperature of returning salt on liquid level of salt tank was illustrated. A series of measures were put forward to prevent molten salt block accident. The improved startup and shutdown mode is relatively inexpensive and reliable. |
| Close |