| Study of Antimony Removal from Zinc Leachate in NH3-NH4Cl-H2O System |
|
Received:July 02, 2014
Revised:July 05, 2014
Accepted:July 07, 2014
Published Online:November 19, 2014
|
| View Full Text View/Add Comment Download reader |
| DOI:10.3969/j.issn.1007-7545.2014.12.002 |
| KeyWord:NH3-NH4Cl-H2O system; antimony removal; ferrous chloride; hydrogen peroxide; zinc |
| Author | Institution |
| WANG Rui-xiang |
江西理工大学冶金与化学工程学院 |
| ZHANG Zhao-xue |
江西理工大学冶金与化学工程学院 |
| MAO Ji-yong |
江西理工大学冶金与化学工程学院 |
| XIE Bo-yi |
江西理工大学冶金与化学工程学院 |
| XIONG Jia-chun |
江西理工大学冶金与化学工程学院 |
|
| Hits: 2312 |
| Download times: 2627 |
| Abstract: |
| Antimony in zinc column leached solution from zinc oxide ore in NH3-NH4Cl-H2O system was removed by hydrocolloids coprecipitation method. The results show that concentration of antimony is reduced from 7.4 mg/L to 0.3 mg/L with antimony removal rate of 95% under the conditions including dosage of ferrous chloride of 2 g/L, dosage of hydrogen peroxide of 1.2 mL/L, and stirring time of 40 min at room temperature. The antimony removal solution can meet requirement of zinc electrowinning. |
| Close |