Numerical Simulation of Electric Field in 60 kA Immersion Rare Earth Electrolytic Cell |
Received:August 20, 2014 Revised:August 28, 2014 |
View Full Text View/Add Comment Download reader |
DOI:10.3969/j.issn1007-7545.2015.02.009 |
KeyWord:60 kA rare earth electrolyzer; numerical simulation; electric filed; optimization |
Author | Institution |
WU Yong-fu |
内蒙古科技大学 能源与环境工程学院 |
Zhang Xue-jiao |
内蒙古科技大学 能源与环境工程学院 |
Chen Si-qi |
大唐科技产业集团有限公司安徽分公司 |
LIU Zhong-xing |
内蒙古科技大学 能源与环境工程学院 |
Dong Yun-fang |
内蒙古科技大学 能源与环境工程学院 |
|
Hits: 1182 |
Download times: 1334 |
Abstract: |
Basic size structure of new 60 kA immersion rare earth electrolytic cell was designed and developed by calculation. Three dimensional electric field calculation model of electrolyzer was established with numerical simulation software. Distribution of electric field in rare earth electrolytic cell with polar distance of 60~100 mm was simulated. Analysis results of electric field voltage show that the optimum electrode spacing is 70 mm. This simulation results can provide theoretical basis for commercialization and application of this type of electrolyzer. |
Close |