Analysis of Heat Transfer Process in Reduction Equipment of Titanium Sponge Production by Magnesiothermic Reduction
Received:September 24, 2014   Revised:September 28, 2014   Accepted:September 29, 2014      Published Online:December 24, 2014
View Full Text  View/Add Comment  Download reader
DOI:10.3969/j.issn.1007-7545.2015.01.009
KeyWord:titanium sponge; forced heat; convective heat transfer; cooling air
        
AuthorInstitution
anhonghao 贵州大学
WU Fu-zhong 贵州大学
JIN Hui-xin 贵州大学
Hits: 2215
Download times: 2670
Abstract:
      Based on thermal test data, the thermal of cooling air in reduction process was calculated and analyzed to establish an algebraic relationship between feed rate of TiCl4 and air heat radiation intensity which is applied to evaluate feed rate of TiCl4. The results indicate that feed rate relates with wind speed and outlet temperature of cooling air within a certain range. Evaluation value of feed rate according to wind speed and outlet temperature of cooling air can be obtained and applied to predict range of feed rate.
Close