| Study on Conductivity of Electrolyte of Flow Line Magnesium Cell |
|
Received:January 15, 2015
Revised:January 20, 2015
Accepted:January 22, 2015
Published Online:May 20, 2015
|
| View Full Text View/Add Comment Download reader |
| DOI:doi:10.3969/j.issn.1007-7545.2015.06.008 |
| KeyWord:flow line magnesium cell; conductivity; electrolyte |
| Author | Institution |
| MA Shangrun |
攀钢集团研究院有限公司 |
| ZHU Fuxing |
攀钢集团研究院有限公司 |
| MU Tianzhu |
攀钢集团研究院有限公司 |
| ZHENG Quan |
攀钢集团研究院有限公司 |
|
| Hits: 2166 |
| Download times: 2243 |
| Abstract: |
| Variation laws of conductivity of flow line magnesium cell electrolyte under different temperature, different content of electrolysis residue, and electrolyte component were investigated. The results show that in MgCl2-NaCl-KCl ternary system, rising of temperature and amount of electrolytic residue will cause increase of conductivity while rising of MgO content and MgCl2 concentration will cause drop of conductivity. The conductivity drops first and then rises when KCl content increases with constant MgCl2 concentration. |
| Close |