Removal of Residual Organics in Manganese Electrochemical Solution by Fenton Process
Received:March 10, 2015  Revised:March 13, 2015
View Full Text  View/Add Comment  Download reader
DOI:doi:10.3969/j.issn.1007-7545.2015.10.005
KeyWord:manganese electrochemical solution; Fenton Process; removal; organics
           
AuthorInstitution
CHEN Nanxiong 广西大学化学化工学院
MING Xian-quan 中信大锰矿业有限责任公司
WANG Yu-hong 广西大学化学化工学院
SU Hai-feng 广西大学化学化工学院
Hits: 2707
Download times: 2513
Abstract:
      Fenton reagent was introduced to remove residual organics in manganese electrochemical solution by oxidation treatment, and variations of COD values of solution were measured to evaluate the removal effects. The effects of initial pH value, ferrous ions concentration, H2O2/Fe2 molar ratio, reaction time and temperature on COD removal rate were investigated. The results show that COD removal rate is 75.35% under the conditions including initial pH value of 3.50, ferrous ions concentration of 0.03 mol/L, H2O2/Fe2 molar ratio of 5, reaction temperature of 30 ℃, and reaction time of 60 min.