Study on Antimony Electrowinning from Sodium Sulphide Alkaline Leaching Solution of Antimony-bearing Gold Concentrates
Received:April 09, 2015  Revised:April 15, 2015
View Full Text  View/Add Comment  Download reader
DOI:doi:10.3969/j.issn.1007-7545.2015.10.006
KeyWord:antimony-bearing gold concentrates; sodium sulphide alkaline leaching solution; antimony electrowinning
              
AuthorInstitution
Zhang Lizheng 招金矿业股份有限公司
Jin Rangong 北京矿冶研究总院
Qi Xingchuan 甘肃招金贵金属冶炼有限公司
Li Yun 北京矿冶研究总院
Wang Yun 北京矿冶研究总院
Hits: 2588
Download times: 3199
Abstract:
      Antimony was electrodeposited from sodium sulphide alkaline leaching solution of antimony-bearing gold concentrates by electrochemical process. Electrodeposition parameters were optimized and trend of gold was investigated. The results show that gold deposits on cathode board together with antimony under the conditions including electrodeposition temperature of 50 ℃ , and current density of 250 A/m2. Purity of cathode antimony is 97.12% with gold content of 22 g/t. Quality of cathode antimony can be effectively improved by adding polyethylene glycol and reducing current density.