| Technical Condition Optimization for 400 kA Aluminum Electrolyzer with Graphitization Cathode |
|
Received:July 03, 2015
Revised:July 07, 2015
Accepted:July 10, 2015
Published Online:December 24, 2015
|
| View Full Text View/Add Comment Download reader |
| DOI:10.3969/j.issn.1007-7545.2016.01.005 |
| KeyWord:400 kA aluminum electrolyzer; graphitization cathode; optimization |
| Author | Institution |
| LIQING |
河南省工业学校 |
| CUIJINSHUI |
万基控股集团有限公司 |
|
| Hits: 2045 |
| Download times: 2933 |
| Abstract: |
| Technical conditions of 400 kA aluminum electrolyzer with graphitization cathode were optimized, including maintaining lower aluminum level, addressing incrustation on pot bottom, adjusting electrolyte component by controlling composition of raw materials, reducing lithium content and superheat degree, maintaining suitable molecular ratio and etc. Current efficiency is 90% above and power consumption for one tonnage aluminum is below 13 600 kWh after optimization. |