Continuous Expanding Test on Slurry Electrolysis of As-rich Antimonic Gold Concentrate
Received:August 04, 2015   Revised:August 04, 2015   Accepted:August 05, 2015      Published Online:November 18, 2015
View Full Text  View/Add Comment  Download reader
DOI:doi:10.3969/j.issn.1007-7545.2015.12.002
KeyWord:slurry electrolysis; antimonic gold concentrate; antimony; arsenic; gold
              
AuthorInstitution
CHEN Yong-qiang 北京科技大学
LIU Yong 湖南黄金集团
WANG Cheng-yan 北京科技大学
YANG Yong-qiang 北京矿冶研究总院
ZHANG Yong-lu 北京矿冶研究总院
Hits: 2438
Download times: 2214
Abstract:
      Slurry electrolysis was successfully utilized to process As-rich antimonic gold concentrate in semi-pilot tests. The results show that antimony recovery is 97% above. Gold and most antimony and sulfur are enriched in leached residue. Hazards of generation of vast arsenic-alkali residue and low-concentration SO2 gas were avoided. The consumption of industrial hydrochloric acid is 286 kg for one ton production of antimony. Moreover, the total electricity consumption is about 3 389 kWh and the direct current consumption is 1 318 kWh for one ton production of antimony.