solvent extraction; Versatic10; calcium; magnesium; cobalt; nickel
Received:October 01, 2015   Revised:October 08, 2015   Accepted:October 09, 2015      Published Online:February 23, 2016
View Full Text  View/Add Comment  Download reader
DOI:10.3969/j.issn.1007-7545.2016.03.001
KeyWord:solvent extraction; Versatic 10; cobalt; nickel
                 
AuthorInstitution
GUAN Qing-jun 中南大学 资源加工与生物工程学院
LUO Peng-hui 茂盛矿业赞比亚有限公司
GUO Liang 茂盛矿业赞比亚有限公司
SUN Wei 中南大学 资源加工与生物工程学院
Yin Zhigang 中南大学 资源加工与生物工程学院
ZOU Xing 北京科技大学
Hits: 2396
Download times: 2614
Abstract:
      Nickel(Ⅱ) and cobalt(Ⅱ) were simultaneously extracted from magnesium and calcium synthetic sulphate solution by carboxylic extractant Versatic10. The optimum extraction conditions include temperature of 25 ℃, oscillation intensity of 200 r/min, oscillation duration of 4 min, initial pH of 2.5, O/A=1/3, and saponification rate of 60%. After washing twice with deionized water at pH 5.70 and O/A=1/1, the co-extraction rates of calcium and magnesium are both 0.5% below. The stripping rates of nickel and cobalt are both 99% above by 2 mol/L sulfuric acid and O/A=1/1.
Close