Microbial Column Leaching Series Test of Uranium Ore
Received:November 23, 2015   Revised:November 25, 2015   Accepted:November 27, 2015      Published Online:April 18, 2016
View Full Text  View/Add Comment  Download reader
DOI:doi:10.3969/j.issn.1007-7545.2016.05.006
KeyWord:series process; uranium ore; microbial leaching; leaching rate
        
AuthorInstitution
LIANG sheng 东华理工大学水资源与环境工程学院
WANG Xuegang 东华理工大学水资源与环境工程学院
SUN Zhanxue 东华理工大学水资源与环境工程学院
Hits: 2030
Download times: 2699
Abstract:
      The effect of column leaching series process on uranium leaching rate was investigated with mixed uranium ore as raw material. The results show that within 130 days, uranium leaching rate of Z1、Z2、Z3 is 81.83%, 78.89%, and 81.43% respectively, acid consumption is 10.73%, 10.73%, and 11.08% respectively. The series process can effectively balance uranium concentration in leaching solution, improve adsorption efficiency of uranium and promote leaching of uranium.