Numerical Simulation of Lead Vapor Contamination Diffusion Process in Industrial Production of Molten Lead
Received:December 13, 2015   Revised:December 20, 2015   Accepted:December 23, 2015      Published Online:May 19, 2016
View Full Text  View/Add Comment  Download reader
DOI:doi:10.3969/j.issn.1007-7545.2016.06.019
KeyWord:lead vapor; molten lead pot; negative pressure plate; numerical simulation
        
AuthorInstitution
XIE kai 中南大学 能源科学与工程学院
LI qi 中南大学 能源科学与工程学院
MI sha 中南大学 能源科学与工程学院
Hits: 1983
Download times: 1887
Abstract:
      Entity model of smelting and refining of crude lead was built for three-dimensional numerical simulation of lead vapor collection during lead smelting and investigation of flow characteristics of molten lead pot and negative pressure plate. The results show that calculation results agree well with test data. Volume fraction of lead vapor is small and most of gas is air in side suction hood. The heavy lead vapor is easy to sink and cannot be collected into suction tube. The collection efficiency of lead vapor in suction tube is not ideal as only as 1.1%.