| Numerical Simulation of Lead Vapor Contamination Diffusion Process in Industrial Production of Molten Lead |
|
Received:December 13, 2015
Revised:December 20, 2015
Accepted:December 23, 2015
Published Online:May 19, 2016
|
| View Full Text View/Add Comment Download reader |
| DOI:doi:10.3969/j.issn.1007-7545.2016.06.019 |
| KeyWord:lead vapor; molten lead pot; negative pressure plate; numerical simulation |
| Author | Institution |
| XIE kai |
中南大学 能源科学与工程学院 |
| LI qi |
中南大学 能源科学与工程学院 |
| MI sha |
中南大学 能源科学与工程学院 |
|
| Hits: 1983 |
| Download times: 1887 |
| Abstract: |
| Entity model of smelting and refining of crude lead was built for three-dimensional numerical simulation of lead vapor collection during lead smelting and investigation of flow characteristics of molten lead pot and negative pressure plate. The results show that calculation results agree well with test data. Volume fraction of lead vapor is small and most of gas is air in side suction hood. The heavy lead vapor is easy to sink and cannot be collected into suction tube. The collection efficiency of lead vapor in suction tube is not ideal as only as 1.1%. |