Separation of Zinc and Cobalt from Solution with P204
Received:January 11, 2016   Revised:January 14, 2016   Accepted:January 18, 2016      Published Online:May 19, 2016
View Full Text  View/Add Comment  Download reader
DOI:doi:10.3969/j.issn.1007-7545.2016.06.007
KeyWord:P204; extraction; zinc; cobalt; separation
        
AuthorInstitution
LI Qiang 三明学院 资源与化工学院 福建三明
WANG Hai Yu 三明学院 资源与化工学院 福建三明
HUANG Hui 三明学院 资源与化工学院 福建三明
Hits: 2293
Download times: 2239
Abstract:
      Zinc and cobalt were extracted from solution with P204 as extractant. The effects of relevant factors on extraction were investigated. The results show that extraction ratio of single stage of zinc and cobalt is about 35% and 2% respectively under the optimum conditions including pH of aqueous phase of 4, O/A=1.0, P204 concentration of 10%, extraction time of 10 min, and oscillation rate of 100 r/min. Zinc extraction ratio of four stage is 98%.
Close