Study on Lead Emission Characteristic from Dust of Lead Smelter
Received:May 06, 2016   Revised:May 13, 2016   Accepted:May 16, 2016      Published Online:September 20, 2016
View Full Text  View/Add Comment  Download reader
DOI:doi:10.3969/j.issn.1007-7545.2016.10.017
KeyWord:lead and zinc smelting; smoke; lead; emission characteristic
  
AuthorInstitution
Liu Dajun 环境保护部环境工程评估中心
Hits: 1821
Download times: 2167
Abstract:
      Atmospheric pollution source and ambient air from four different lead smelters with four different processes were monitored and analyzed. The results show that average lead concentration in PM10 of outlet smoke of ISA furnace and blast furnace is 60 μg/m3 and 224 μg/m3 respectively. Based on investigation of organized emissions from two lead smelters, lead in PM10 is mainly distributed in PM2.5 with average of 75%. Based on research on air surrounding and non-organized emission source from two lead smelters, lead in PM10 is mainly distributed in PM2.5 with average of 74.2%, and lead in PM2.5 accounts for 47.5% of lead in TSP. Lead in organized and non-organized emissions source is mainly distributed in PM10, especially in PM2.5.