Study on Treatment of Wastewater after Silver Extraction from Waste Plasma Screen by Hydrometallurgy
Received:June 13, 2016   Revised:June 14, 2016   Accepted:June 20, 2016      Published Online:September 20, 2016
View Full Text  View/Add Comment  Download reader
DOI:doi:10.3969/j.issn.1007-7545.2016.10.018
KeyWord:plasma display panel; hydrometallurgy; neutralization; flocculation; evaporation
                    
AuthorInstitution
CHEN Wei 昆明理工大学环境科学与工程学院
Ning Ping 昆明理工大学环境科学与工程学院
Yuan Cui-yu 湖南有色金属研究院
OUYANG Kun 湖南有色金属研究院
WAN Si 湖南有色金属研究院
WANG Bing 湖南有色金属研究院
ZHU An-ling 湖南有色金属研究院
Hits: 1708
Download times: 1639
Abstract:
      Waste water from silver extraction by hydrometallurgy from waste plasma display panels was treated by neutralization oxidation flocculation, evaporation, and neutralization flocculation evaporation, respectively. The results show that neutralization flocculation evaporating method has high removal efficiency for heavy metals and COD, and can also achieve basic equilibrium in wastewater treatment and recycling cost value by recovery of nitric acid and sale of neutralization residues. Moreover, condensed water can be recycled in production process with no effect on production index.