Study on Iron Removal from Cobalt Leaching Solution |
Received:February 13, 2017 Revised:February 28, 2017 |
View Full Text View/Add Comment Download reader |
DOI:doi:10.3969/j.issn.1007-7545.2017.06.004 |
KeyWord:cobalt; lixivium; iron removal; neutralization hydrolysis; potential; pH value |
Author | Institution |
zhangsuchao |
金川集团股份有限公司 镍钴研究设计院 |
Yaolixue |
金川集团股份有限公司 镍都实业公司 |
Lusujun |
金川集团股份有限公司 镍钴研究设计院 |
Zhangpeng |
金川集团股份有限公司 镍钴研究设计院 |
|
Hits: 857 |
Download times: 904 |
Abstract: |
A cobalt smelting plant applyies neutralizing hydrolysis process to remove iron. Process of iron removal has low iron removal rate and high cobalt entrainment in slag (up to 14%). Iron was removed from lixivium after copper removal by neutralizing hydrolysis process. Effect of parameter on iron removal was investigated. The results show that iron removal rate is 99% and cobalt entrainment rate is 1% below under the conditions including redox potential of 0.40 V, terminal pH value of 4.00~4.25, iron removal time of 6.5 h above, air flow of 0.8 time volum of solution per minute, and temperature of 50 ℃ above. |