| Establishment of Cooling System of Slag Ladle in Copper Smelter |
|
Received:June 30, 2017
Revised:June 30, 2017
Accepted:July 03, 2017
Published Online:October 31, 2017
|
| View Full Text View/Add Comment Download reader |
| DOI:doi:10.3969/j.issn.1007-7545.2017.11.010 |
| KeyWord:copper smelting; copper slag; ladle cooling |
| Author | Institution |
| Li Siyong |
紫金铜业有限公司 |
|
| Hits: 2471 |
| Download times: 2558 |
| Abstract: |
| Requirement of cooling system for slag ladle was analyzed in terms of safe production, flotation process, slag type, copper content of slag, and duration of water-cooling. The results show that natural cooling time for flash smelting slag ladle and converter slag ladle with normal copper in slag is 10 h and 28 h respectively with total cooling time of 60 h and 78 h respectively. On the other hand, natural cooling time for flash smelting slag ladle and converter slag ladle with copper with higher content in slag is 28 h and 48 h respectively with total cooling time of 78 h and 90 h respectively. Deslagging operation upon external wall temperature of slag ladle of 50 ℃ below can reduce molten slag, prevent blasting accidents, and facilitate subsequent process index optimization. |
| Close |
|
|
|