| Nanoscale Fe/Ni bimetal was prepared by synchronous liquid phase method to remove U(VI) from aqueous solution. Nanoscale Fe/Ni bimetal was characterized by BET and SEM. Effects of n(Fe)/n(Ni), pH value, initial U(VI) concentration, adsorption time, and adsorption temperature on remove of U(VI) were investigated by batch test method. The results show that adsorption capacity is 161.91 mg/g at pH=3.5, adsorption time of 30 min, and adsorption temperature of 25 ℃. |