Industrial Test on HAT4045 Cyanide Leaching Tank
Received:May 16, 2018   Revised:May 24, 2018   Accepted:May 24, 2018      Published Online:September 19, 2018
View Full Text  View/Add Comment  Download reader
DOI:doi:10.3969/j.issn.1007-7545.2018.10.010
KeyWord:HAT4045 cyanide leaching tank; industrial test; dissolved oxygen; mixing; leaching
           
AuthorInstitution
Wu Feng 北京市高校节能矿冶装备工程研究中心 北矿机电科技有限责任公司 北京矿冶科技集团
Dong Ganguo 北京市高校节能矿冶装备工程研究中心 北矿机电科技有限责任公司 北京矿冶科技集团
Lai Maohe 北京市高校节能矿冶装备工程研究中心 北矿机电科技有限责任公司 北京矿冶科技集团
Shi Shuaixing 北京市高校节能矿冶装备工程研究中心 北矿机电科技有限责任公司 北京矿冶科技集团
Hits: 1983
Download times: 2240
Abstract:
      Design principle and main structure characteristics of HAT4045 cyanide leaching tank were introduced. Parallel comparative industrial tests of HAT4045 cyanide leaching tank were carried out. The results show that HAT4045 cyanide leaching tank is agitated evenly with different numbers of aerators opened and concentration of slurry in different depth is basically the same in tank. When the total aeration volume is reduced by 25%, the average dissolved oxygen and gold leaching rates of HAT4045 cyanide leaching tank at different depths are basically the same as those of the comparative tank. When the total aeration volume is the same, the average dissolved oxygen content of HAT4045 cyanide leaching tank at different depths is 26.6% higher than that of the comparative tank, and gold leaching rate is 3 percentage points higher than that of the comparative tank.
Close