Solvent Extraction of Copper from Ammoniacal/Ammonium Sulfate Medium with Mextral 54-100
Received:July 03, 2018   Revised:July 06, 2018   Accepted:July 09, 2018      Published Online:October 16, 2018
View Full Text  View/Add Comment  Download reader
DOI:doi:10.3969/j.issn.1007-7545.2018.11.003
KeyWord:Mextral 54-100; β-diketone; solvent extraction; copper
              
AuthorInstitution
Zeng Lei 北京科技大学冶金与生态工程学院
Wang Chengyan 北京科技大学冶金与生态工程学院
Ma Baozhong 北京科技大学冶金与生态工程学院
Chen Yongqiang 北京科技大学冶金与生态工程学院
Xing Peng 北京科技大学冶金与生态工程学院
Hits: 2203
Download times: 1871
Abstract:
      Solvent extraction of copper from ammoniacal/ammonium sulfate medium using Mextral 54-100 was investigsted. Effects of extractant concentration, phase ratio, extraction time and pH value of initial leach solution on copper extraction were examined. The results show that capacity of one-stage copper extraction is 29.66 g/L under the optimum conditions including 40% volume concentration of extractant, phase ratio of O/A=1/1, and extraction time of 4 min. Copper stripping rate with 170 g/L H2SO4 is 92.59% from loaded organic phase. Theoretical stage of extraction is determined by of McCabe-Thiele Isothermy Graphic Method. After two-stage countercurrent extraction, the simulation results correspond with the data, and copper concentration in raffinate is about 0.06 g/L.