Analysis on Voltage Balance of 400 kA Prebake Aluminum Electrolysis Cells
Received:December 17, 2018   Revised:December 21, 2018   Accepted:December 24, 2018      Published Online:March 19, 2019
View Full Text  View/Add Comment  Download reader
DOI:doi:10.3969/j.issn.1007-7545.2019.04.005
KeyWord:prebake anode; 400 kA aluminum electrolysis cells; voltage drop; voltage balance
     
AuthorInstitution
Cao Alin 百色学院材料科学与工程学院;百色学院化学与环境工程学院
Li Chunhuan 百色学院化学与环境工程学院
Hits: 2397
Download times: 1898
Abstract:
      Voltages of prebake aluminum electrolysis cell include anode voltage drop, fixture voltage drop, electrolyte voltage drop, cathode voltage drop, riser busbar voltage drop, anode busbar voltage drop, reversible equilibrium voltage drop and external busbar voltage drop. During aluminum electrolysis production, keep voltage balance is the basic condition for stable and efficient operation. Through analysis of voltage balance measurement on 400 kA pre-bake aluminium cell and combining present production status, the direction and measures for voltage balance adjustment are analyzed and summarized. Energy saving and energy consumption reduction can be effectively achieved through reducing voltage drop of all part, improving production management and strict application of operation rules and regulations.