| Analysis on Voltage Balance of 400 kA Prebake Aluminum Electrolysis Cells |
|
Received:December 17, 2018
Revised:December 21, 2018
Accepted:December 24, 2018
Published Online:March 19, 2019
|
| View Full Text View/Add Comment Download reader |
| DOI:doi:10.3969/j.issn.1007-7545.2019.04.005 |
| KeyWord:prebake anode; 400 kA aluminum electrolysis cells; voltage drop; voltage balance |
| Author | Institution |
| Cao Alin |
百色学院材料科学与工程学院;百色学院化学与环境工程学院 |
| Li Chunhuan |
百色学院化学与环境工程学院 |
|
| Hits: 2397 |
| Download times: 1898 |
| Abstract: |
| Voltages of prebake aluminum electrolysis cell include anode voltage drop, fixture voltage drop, electrolyte voltage drop, cathode voltage drop, riser busbar voltage drop, anode busbar voltage drop, reversible equilibrium voltage drop and external busbar voltage drop. During aluminum electrolysis production, keep voltage balance is the basic condition for stable and efficient operation. Through analysis of voltage balance measurement on 400 kA pre-bake aluminium cell and combining present production status, the direction and measures for voltage balance adjustment are analyzed and summarized. Energy saving and energy consumption reduction can be effectively achieved through reducing voltage drop of all part, improving production management and strict application of operation rules and regulations. |