| Influence of Parameters of External Circulation Water Cooling System on Temperature Drop Rate of Vacuum Casting |
|
Received:April 09, 2019
Revised:April 20, 2019
Accepted:April 22, 2019
Published Online:July 15, 2019
|
| View Full Text View/Add Comment Download reader |
| DOI:doi:10.3969/j.issn.1007-7545.2019.08.008 |
| KeyWord:Fluent; rapid cooling; vacuum suction casting; cooling rate |
| Author | Institution |
| SUN Anna |
上海工程技术大学 |
| HE Tao |
上海工程技术大学 |
| HUO Yuanming |
上海工程技术大学 |
| DONG Xingqian |
上海工程技术大学 |
| WANG Jing |
上海工程技术大学 |
|
| Hits: 1912 |
| Download times: 1946 |
| Abstract: |
| In order to explore cooling rate of vacuum suction casting cooling system, Fluent software was used to model and analyze influence rule of spiral guide plate""s pitch, inlet temperature and inlet velocity on cooling rate of spiral guide plate, and experiment was carried out for verification. The results show that cooling rate drops with increase of inlet flow temperature and drop of inlet flow velocity, and it rises first and then drops with increase of screw pitch. The best cooling effect is obtained under the conditions including screw pitch of spiral plate of 35 mm, inlet velocity of 1.345 m/s, and inlet temperature of 283.15 K. The simulation results are in good agreement with the measured results. |