| Classification Collection of Lead in Waste Paste of Positive and Negative Plate of Waste Lead-acid Battery |
| Received:February 17, 2020 Revised:February 19, 2020 |
| View Full Text View/Add Comment Download reader |
| DOI:doi:10.3969/j.issn.1007-7545.2020.09.006 |
| KeyWord:classification collection; acid leaching; waste lead paste |
| Author | Institution |
| LIU Heng-yi |
广西大学 资源环境与材料学院 南宁 |
| HUANG Kui |
广西大学 资源环境与材料学院 南宁 |
| HUANG Quan-li |
广西大学 资源环境与材料学院 南宁 |
| DONG Hai-li |
广西大学 资源环境与材料学院 南宁 |
| HUANG Chao-ran |
广西大学 资源环境与材料学院 南宁 |
|
| Hits: 1819 |
| Download times: 1806 |
| Abstract: |
| Lead in waste lead paste was recovered classifiably with acid leaching, i.e., positive electrode was leached by acid in heating condition, and negative electrode was directly leached with acid. The results show that anode paste is fully reacted for 24 h with sulfuric acid of mass fraction of 85%(L/S=108 g/L), and conversion rate of PbSO4 is 91.34%. Positive paste material is treated with mass fraction of sulfuric acid of 85%(L/S=108 g/L) for 2 h at 65 ℃, and conversion rate of PbSO4 is 95.69%. Recovered PbSO4 can be used directly after electrolysis or desulfurization crystallization by sodium hydroxide. |