Study on Separation of Selenium and Antimony in Copper Anode Slime Pressure Leaching Solution
Received:March 29, 2020   Revised:April 14, 2020   Accepted:April 15, 2020      Published Online:June 20, 2020
View Full Text  View/Add Comment  Download reader
DOI:doi:10.3969/j.issn.1007-7545.2020.07.013
KeyWord:copper anode slime pressure leaching solution; selenium; tellurium; separation
                 
AuthorInstitution
Zhang denggao 矿冶科技集团有限公司
Jiang xunxiong 矿冶科技集团有限公司
Fan yanqing 矿冶科技集团有限公司
Wang shengdong 矿冶科技集团有限公司
Feng linyong 矿冶科技集团有限公司
Liu wei 矿冶科技集团有限公司
Hits: 2077
Download times: 2602
Abstract:
      Most of copper ions in copper anode slime pressure leaching solution were firstly removed, and then selenium and tellurium were separated by reduction step-by-step. Separation rate of selenium and tellurium is both above 98%. This method solves the problems that selenium cannot completely be precipitated from copper anode slime pressure leaching solution during selenium precipitation process, and high selenium content in subsequent settling of telluride is not conducive to refining and tellurium extraction.
Close