| Study on Adsorption Performance of Modified CoFe2O4 for U(Ⅵ) in Solution |
|
Received:June 01, 2021
Revised:June 02, 2021
Accepted:June 09, 2021
Published Online:July 29, 2021
|
| View Full Text View/Add Comment Download reader |
| DOI:doi:10.3969/j.issn.1007-7545.2021.08.017 |
| KeyWord:cobalt ferrite; acrylamide; uranium; adsorption; mechanism |
| Author | Institution |
| DU Yan-jun |
东华理工大学 |
| CHEN Rong |
东华理工大学 |
| LI Xiao-yan |
东华理工大学 |
| LIU Yi-bao |
东华理工大学 |
| LE Zhang-gao |
东华理工大学 |
|
| Hits: 1655 |
| Download times: 1937 |
| Abstract: |
| CoFe2O4 material was prepared by hydrothermal synthesis method, and influences of pH value, ratio of solid to liquid, time, temperature, and initial U(Ⅵ) concentration on U(Ⅵ) in CoFe2O4 adsorption solution were investigated. The material was characterized by SEM and mechanism of its removal of U(Ⅵ) was analyzed. The results show that CoFe2O4 has a very good removal effect on U(Ⅵ). The maximum adsorption capacity of U(Ⅵ) is 73.9 mg/g under the conditions including pH value of 5.5, ratio of solid to liquid of 0.3 g/L, reaction time of 120 min, and U(Ⅵ) solution concentration of 30 mg/L. |
| Close |
|
|
|