Industrial Test on Removal of Fluorine and Chlorine from Zinc Sulfate Solution with Ion Exchange
Received:July 21, 2021   Revised:July 27, 2021   Accepted:August 02, 2021      Published Online:October 20, 2021
View Full Text  View/Add Comment  Download reader
DOI:doi:10.3969/j.issn.1007-7545.2021.11.002
KeyWord:zinc sulfate solution; fluorine; chlorine; ion exchange; industrial test
                       
AuthorInstitution
ZOU Wei 昆明冶金研究院有限公司
YANG Da-jin 云南驰宏锌锗股份有限公司
LIU Jun-chang 昆明冶金研究院有限公司
QU Hong-tao 云南驰宏锌锗股份有限公司
FU Wei-qin 昆明冶金研究院有限公司
FU Guang 云南驰宏锌锗股份有限公司
ZHANG Te 云南驰宏锌锗股份有限公司
LU Wen-peng 云南驰宏锌锗股份有限公司
Hits: 2153
Download times: 1994
Abstract:
      Industrial experiment on removal of fluorine and chlorine ion from zinc sulfate solution by ion exchange was carried out. Effects of adsorption time, desorption time, and desorption resin pH value on removal of fluorine and chlorine from zinc sulfate solution were studied. The experimental results show that under the optimum process parameters, fluorine and chlorine removing rates is 61.47% and 93.59% respectively during adsorption process. In desorption process, fluorine and chlorine desorption rate is 94.11% and 97.50% respectively. In regeneration process, fluorine and chlorine volatilization rate is 92.66% and 98.66% respectively. The solution in whole process is recycled and waste water discharge is reduced.