Single-Membrane Double-Chamber Electrodeposition Process of Manganese Metal
Received:August 30, 2023   Revised:September 07, 2023   Accepted:September 11, 2023      Published Online:November 30, 2023
View Full Text  View/Add Comment  Download reader
DOI:doi:10.3969/j.issn.1007-7545.2024.01.002
KeyWord:single-membrane double-chamber; electrolytic manganese; influence factor;current efficiency; selenite acid
              
AuthorInstitution
LIU Bo 兰州交通大学环境与市政工程学院
SONG Xiaosan 兰州交通大学环境与市政工程学院
SONG Xichen 兰州交通大学环境与市政工程学院
YUE Zilin 兰州交通大学环境与市政工程学院
FAN Jishuo 兰州交通大学环境与市政工程学院
Hits: 1669
Download times: 1583
Abstract:
      In view of the toxic and harmful effects of manganese-containing wastewater, anion-exchange membrane was proposed instead of diaphragm to treat manganese-containing wastewater. First, the single factor method test was used to explore the optimum process parameters, and under the optimum conditions, the current efficiency is 71.36%, the recovery rate of manganese is 85.6%, the recovery rate of acid is 77.23%, and the energy consumption is 7 784.78 kWh/t. The macroscopic form of electrolytic manganese is smooth and homogeneous with metallic luster. The results of SEM and XRD analysis on the effect of different concentration of selenite on electrolytic manganese show that, when the selenite is 0.07 g/L, the microstructure of electrolytic manganese is uniform, densely packed, smooth, dendrite free and with minimum voids. The electrolytic manganese prepared is α-Mn with good crystallinity.